Emerson 15A0026H08 Ovation Safety Function Module

Emerson 15A0026H08 Ovation safety function module, upgraded hardware revision for safety‑related signal processing, improves safety channel diagnosis and anti‑interference performance, used for thermal power plant Ovation DCS system maintenance and renovation。
Send Inquiry

Products Description


Emerson 15A0026H08 Ovation Safety Function Module



Technical Specifications

Model:15A0026H08

Brand:Emerson

Product Type:Safety Function Module

Applicable System:Emerson Ovation DCS distributed control system, thermal power plant boiler and turbine safety interlock control cabinet

Supply Voltage:24VDC

Interface:Ovation rack backplane connector, safety signal input‑output terminal port, status debugging interface

Common Revision:Multiple hardware revisions available

Status Indicator:On‑board LED for power, running status, safety channel status, channel error and fault diagnostic indication

Built‑in Function:Enhanced safety interlock logic processing, safety signal acquisition and output, multi‑level channel fault self‑diagnosis, improved safety‑signal voting judgment, hot‑swap support, safety‑loop real‑time monitoring, safety‑abnormality alarm, interference‑resistant signal filtering

Working Temperature:0℃ ~ +60℃

Storage Temperature:‑20℃ ~ +70℃

Protection Class:IP20

Mounting:Ovation standard rack slot‑in installation

Weight:0.42kg


Product Brief:

15A0026H08 is upgraded‑revision safety function module of Emerson Ovation DCS system, succeeding 15A0026H06. It undertakes safety‑related signal collection, logic voting and interlock output for boiler, turbine and other critical equipment in thermal power plants. Compared with H06 version, it optimizes hardware circuit, strengthens channel fault identification and signal filtering capability, adapts to harsh electromagnetic field environment on site. It monitors safety‑loop working state in real‑time and triggers protective interlock under abnormal conditions. It supports hot‑swap, online module replacement without cutting off system power supply. Multi‑group LED indicators intuitively display power‑on, operation, safety‑channel and fault status for convenient on‑site inspection and rapid fault location. This is EOL discontinued spare part,widely used for maintenance and renovation of thermal power plant Ovation DCS system. Please confirm hardware revision and controller firmware matching before purchase. Strict ESD anti‑static protection shall be followed during installation and replacement


Leave Your Message