NI PCI-5402 PCI Bus 14-Bit Function Waveform Generator Board

NI PCI-5402,PCI waveform generator,1CH,14-bit,100MS/s,20MHz bandwidth,50/75Ω,DDS,RTSI sync,modulation,0~50℃,automated stimulus test maintenance.
Send Inquiry

Products Description


NI PCI-5402 PCI Bus 14-Bit Function Waveform Generator Board


Technical Specifications

Model:PCI-5402

Brand:NI

Part No:PCI-5402

Product type:PCI Bus DDS Function Waveform Generator Board

DAC:14-bit resolution

Analog Output:1 channel

Max update rate:100MS/s,effective up to 400MS/s with interpolation

Max sine/square frequency:20MHz

Output impedance:software selectable 50Ω /75Ω

Output amplitude:10Vpp into 50Ω load,20Vpp high impedance

Function:DDS direct digital synthesis,AM/FM/PM modulation,selectable analog filter,external reference clock,external trigger,RTSI multi-board synchronization

Bus:32-bit PCI

Dimension:175mm107mm20mm

Weight:0.22kg

Operating temperature:0℃ ~ +50℃

Storage temperature:-20℃ ~ +70℃

Relative humidity:10~90% non-condensing

Certification:CE

System compatibility

PCI-5402 belongs to NI waveform generator platform.It works with standard PCI industrial PC,supported by NI-FGEN driver and LabVIEW,widely used for stimulus signal simulation,component characterization and automated test bench signal generation in legacy ATE systems.It is spare part for legacy test equipment overhaul.

Function

PCI-5402 is PCI-based DDS function generator with 14-bit resolution.It generates sine,square,triangle,ramp,DC and noise waveforms,supports amplitude/frequency/phase modulation.Selectable output impedance and built-in reconstruction filter ensure clean signal quality.RTSI bus supports multi-card synchronous output for multi-channel stimulus-response measurement systems.

Installation

Insert PCI-5402 into computer PCI slot and fasten bracket.Connect signal cables to BNC connectors.Install NI-FGEN instrument driver.Take ESD protection before installation.

Interface

‑BNC waveform output connector

‑BNC reference clock input connector

‑PFI/SYNC SMB trigger connector

‑PCI gold finger edge connector

‑Board status indicator

Feature

PCI-5402 classic NI PCI DDS waveform generator board.Typical faults:BNC connector oxidation,output amplifier damage,DDS clock circuit failure.Inspect waveform output and amplitude calibration before replacement.

Diagnostic

Fault phenomenon:no waveform output,amplitude abnormal,frequency deviation,synchronization failure.Check BNC cable,termination resistor,PCI slot contact,NI-FGEN driver and impedance configuration.



Product Brief

PCI-5402 is NI PCI bus 1-channel 14-bit waveform generator board with 100MS/s update rate and 20MHz bandwidth,supporting DDS modulation and RTSI synchronization,for signal stimulus testing and legacy automated test equipment renovation.Mainly used for maintenance and replacement of old test equipment.ESD protection must be followed during handling.


Leave Your Message


Leave a message