Products Description
KEBA FM265/A Profibus DP Communication Module

Technical Specifications
Model:FM265/A
Brand:KEBA
Product type:Rack mount Profibus DP slave communication module
Power supply:24 Vdc,19.2~28.8V tolerance,max 0.5A
Control function:Profibus DP data transmission,fieldbus signal conversion,data exchange,signal isolation,communication status monitoring,hardware self-diagnosis,fault indication
Communication:Profibus DP + Kemro K2 backplane bus
Mounting:Plug-in rack slot installation
Operating temperature:-10~55℃
Storage temperature:-20~70℃
Relative humidity:5~95% non-condensing
Max working altitude:2000m
Weight:0.14kg
Dimension:120mm32.5mm100mm
Certification:CE
Protection class:IP20
System compatibility
FM265/A belongs to KEBA Kemro K2 control system family,matched with KEMRO-BUS-8 backplane,CPU modules and I/O modules.Widely applied in injection molding,die-casting machine control cabinets.This is a discontinued legacy fieldbus communication module for equipment maintenance spare replacement.
Function
FM265/A serves as KEBA rack Profibus DP slave communication module.It realizes data interaction between Kemro K2 controller and external Profibus DP field devices,converts internal backplane bus signal into standard Profibus DP bus signal.It supports baud rate from 9.6kbit/s up to 12Mbit/s,adopts galvanic isolation design to avoid interference between field bus and control backplane.It monitors real-time communication status and feeds back fault information to the main controller via backplane bus.It acts as fieldbus communication gateway component for Kemro K2 modular control system.
Installation
Insert FM265/A into the designated rack slot and lock the latch.Complete Profibus DP bus wiring and terminal resistor setting according to wiring drawing.Check bus termination,24V power polarity and cabinet grounding before power-on.
Interface
‑24Vdc power input terminal
‑Profibus DP bus connector
‑Kemro K2 backplane gold finger connector
‑Communication status and fault LED indicator
Circuit feature
Built-in ESD and surge suppression circuit,galvanic signal isolation design,strong anti-interference performance for industrial cabinet environment.
Feature
FM265/A is obsolete KEBA series spare part.Typical failures include communication interruption,bus signal distortion,LED no display,connector oxidation.Check module circuit,gold fingers and bus interface before replacement.This module must match Kemro K2 series rack system,direct substitution without inspection is not recommended.
Diagnostic
When bus short-circuit,communication timeout or internal hardware fault occurs,the module triggers protection and lights up fault LED.
Built‑in function:Profibus DP slave communication,bus data exchange,galvanic isolation,communication status monitoring,self-diagnosis and fault alarm,used as KEBA Kemro K2 series fieldbus communication module spare replacement.

Product Brief
FM265/A is KEBA old industrial rack Profibus DP communication module for injection molding and die-casting machine automation equipment.Confirm compatibility with Kemro K2 backplane before ordering.ESD protection required during handling and installation.