KEBA BL460/A Kemro K2-400 Bus Coupling Module

KEBA BL460/A,Kemro K2-400 bus coupling module,24Vdc supply,for machinery control system data transmission,legacy industrial automation spare replacement.
Send Inquiry

Products Description


KEBA BL460/A Kemro K2-400 Bus Coupling Module



Technical Specifications

Model:BL460/A

Brand:KEBA

Product type:Kemro K2-400 bus coupling module

Power supply:24 Vdc,max 0.9A

Control function:Fieldbus data exchange,signal transmission,bus signal isolation,hardware self-diagnosis,communication fault indication

Communication:CAN bus,internal backplane bus

Mounting:DIN rail mounting

Operating temperature:-10~55℃

Storage temperature:-20~70℃

Relative humidity:5~95% non-condensing

Max working altitude:2000m

Weight:0.45kg

Dimension:175mm110mm40mm

Certification:CE

Protection class:IP20

System compatibility

BL460/A belongs to KEBA Kemro K2-400 control system family,matched with KEBA CPU and I/O modules.Widely applied in plastic machinery and automated equipment control cabinets.This is a discontinued legacy bus coupling module for equipment maintenance spare replacement.

Function

BL460/A serves as KEBA Kemro K2-400 bus coupling module.It realizes data transmission and signal isolation between main controller and distributed I/O modules.It converts and forwards bus signals,monitors bus communication status in real time,and reports communication errors to the host controller.It acts as the bus interface component of KEBA machinery control system.

Installation

Mount BL460/A on standard DIN rail.Finish power and bus wiring according to wiring drawing.Check 24V power polarity and cabinet grounding before power-on.

Interface

‑24Vdc power terminal

‑CAN bus port

‑Backplane bus connector

‑Communication and fault LED indicator

Circuit feature

Isolated bus circuit,built-in ESD and surge suppression design.Stable bus data transmission,strong anti-interference performance for industrial cabinet environment.

Feature

BL460/A is obsolete KEBA series spare part.Typical failures include communication interruption,signal distortion,indicator fault.Check module circuit and connector pins before replacement.This module must match corresponding Kemro K2-400 rack system,direct substitution without inspection is not recommended.

Diagnostic

When bus disconnection,signal interference or internal hardware fault occurs,the module uploads fault information to host controller and lights up fault LED.

Built‑in function:Fieldbus signal conversion,data transmission,signal isolation and communication diagnosis,used as KEBA Kemro K2-400 series bus coupling module spare replacement.


Product Brief

BL460/A is KEBA old industrial series bus coupling module for plastic machinery and automated production equipment.Confirm Kemro K2-400 system matching before ordering.ESD protection required during handling and installation.