Products Description
Teledyne Detcon FP-700 Gas Detector

Feature & Principle
It is a smart combustible gas detector of Teledyne Detcon 700 series, adopting catalytic bead detection principle. When combustible gas contacts the catalyst bead, oxidation reaction occurs and causes resistance change, the internal circuit converts the signal into LEL concentration value. It supports non-intrusive magnetic calibration, built-in LED display for concentration and fault status. The sensing probe is field pluggable and replaceable, with anti-poisoning design, encapsulated electronic circuit and surge protection, suitable for long-term stable monitoring in corrosive, humid and vibration hazardous sites.
Specifications
Model: FP-700 Brand: Teledyne Detcon Sensing principle: Catalytic bead Measuring range: 0~50%LEL / 0~100%LEL Output signal: 4-20mA, Modbus RS485 Power supply: 24VDC Enclosure material: Electropolished 316 stainless steel Response time: T90<30s Safety certification: SIL2, ATEX, IECEx Protection class: IP66 Operation mode: Magnetic non-intrusive calibration
Components & Diagnostics
Catalytic bead sensing cartridge, encapsulated main circuit board, 4-digit LED display, explosion-proof stainless steel housing, calibration port, cable gland assembly. Common faults: sensor poisoning, sensitivity drift, signal loss, calibration failure, moisture ingress.
Product Brief
Teledyne Detcon FP-700 combustible gas detector, gas safety spare widely used for petrochemical, tank farm and offshore platform flammable gas monitoring system overhaul and replacement.