Products Description
Emerson Asco P152 Dust Sensor

Feature & Principle
It is an electrostatic induction dust sensor. When charged dust particles pass through the sensing probe, induced charge signals are generated. The electronic unit converts weak charge signals into standard 4-20mA analog output proportional to dust concentration. It can detect bag breakage and dust leakage of dust collectors. Intrinsically safe models are suitable for hazardous explosion zones, with self-check and fault diagnosis functions.
Specifications
Model: P152 Brand: Emerson Asco Measured medium: Flue gas with particulate dust Output: 4-20mA Type: Intrinsically safe / general type optional Mounting: Pipeline insertion type Protection: NEMA 4X Application: Baghouse dust collector, power plant, cement plant, waste incineration flue gas monitoring Certification: ATEX, CE
Components & Diagnostics
Sensing probe, signal electronic module, cable assembly, mounting fitting. Common faults: signal drift, probe contamination, cable damage, no output.
Product Brief
P152 particulate dust sensor, Emerson Asco flue gas monitoring spare widely used for dust collector overhaul and replacement.