Products Description
Endress+Hauser 5L4C50-7DR3 Proline Promag L400 Electromagnetic Flowmeter Unit

Based on Faraday electromagnetic induction principle. Induced voltage generated by conductive fluid passing through measuring tube is captured by electrodes, converted to standard 4-20mA and HART digital signal. It has no internal moving parts and no pressure loss. Built-in Heartbeat Technology realizes continuous self-verification, detecting electrode fouling, empty pipe and circuit fault without process interruption.
Certification: CE, IEC
Measuring tube with liner and electrode, transmitter unit, touch display, process flange and terminal housing. Common faults: electrode scaling, empty pipe alarm, zero drift and HART communication failure.